The HYDEN375-A ‘Lube Alarm’ unit is a microcontroller based product that allows
the condition of an Easilube system to be accurately monitored. The unit can alert
the machine operator of the following situations:

a) Pump or general system failure
If the grease main-line does not see adequate pressure within a selectable time
period (since the last pump cycle) an alarm will sound and the ‘Grease Pressure’
indicator will illuminate. Refer to section 2.3 for adjustment of ‘fail period’.
b) Reservoir low level
When the reservoir grease level becomes low an alarm will sound and the low
level indicator will illuminate. Note that this function is only available with a
compatible grease reservoir fitted with a low level switch.

For both functions, the LED will illuminate continuously and the alarm will sound
for 60 seconds every 5 minutes to remind the operator. For Grease Pressure
faults, the ‘fail period’ can be reset by pushing the ‘Fault Reset’ button.

MANUAL: 06500636A

VIEW MANUAL

SKU: HYDEN375-A. Categories: , . Brands: , .

The HYDEN375-A ‘Lube Alarm’ unit is a microcontroller based product that allows
the condition of an Easilube system to be accurately monitored. The unit can alert
the machine operator of the following situations:

a) Pump or general system failure
If the grease main-line does not see adequate pressure within a selectable time
period (since the last pump cycle) an alarm will sound and the ‘Grease Pressure’
indicator will illuminate. Refer to section 2.3 for adjustment of ‘fail period’.
b) Reservoir low level
When the reservoir grease level becomes low an alarm will sound and the low
level indicator will illuminate. Note that this function is only available with a
compatible grease reservoir fitted with a low level switch.

For both functions, the LED will illuminate continuously and the alarm will sound
for 60 seconds every 5 minutes to remind the operator. For Grease Pressure
faults, the ‘fail period’ can be reset by pushing the ‘Fault Reset’ button.